Sites
Outstanding actions
On site
Auto-advance suits routine visual inspections, where most answers are
compliant. It pauses on any answer needing a note, a category or a measurement.
Equipment
Instruments used to take a measurement are recorded here with their
calibration position, and named in the report. A measured value from an unidentified or
out-of-calibration instrument carries little weight.
Inspector details
Recorded once and used to pre-fill the sign-off on every inspection. You can
amend any of it at the point of signing; the wording used on the day is what appears in the
report.
Enter one statement per line. Each becomes an option in the drop-down at
sign-off, so a different basis can be selected for different work. A consistent statement
across reports carries more weight than one worded differently each time. Rope access
certification is recorded separately below.
Backup and transfer
Export everything to move to a new device or to keep a copy off this one.
Export a single site when handing work to someone else — a whole-device backup would give
them every client you hold. Importing merges records; anything already present is left as it
is.
Sync between devices
Sends the sites on this device to a shared store and brings back whatever is
newest for each site, so this device and any other with the same sync key converge. Photos sync
too, but only as low-resolution thumbnails to keep this quick over a phone connection — use
Backup and transfer above to move full-resolution originals between devices.
Build
This device is running build .
New site
Structures
Equipment and PPE
Open defects
Trial data
One row per question answered, across every inspection on this site.
Open it in a spreadsheet to see which checks never produce findings, which are always
marked not applicable, and how long each tier actually takes.
New structure
Where the manual is held online, record the address. It is the same address
a QR code on the marking notice would point to, so recording it here keeps the plate and the
record pointing at the same document. Clause 6 requires the manual to be provided; a link
does not discharge that, and the duty holder still needs their own copy.
The standard defers to the manufacturer's stated interval, between one and
three months. Where no manual is held, one month is the safe assumption.
Declaration of anchor use
Where no person with authority is available, record the position from
observation and seek written confirmation afterwards. An inspector's observation is not a
declaration by the duty holder and the report will distinguish between the two.
Protection point map
Signage
Findings carried forward
Anchor devices (BS EN 795)
Generates an anchor device installation record for this structure's
register, to BS EN 795:2012 with regard to BS 7883:2019. Fields the register does not
hold — fixings, torque, proof loading — are left for completion by the installer.
Auto-belay devices
Start an inspection
Inspection history
For the marking notice only. Clause 5 e) requires this date to be shown.
Record what it says, even where it has passed.
Name the document this came from. The report states that the finding was
reported by others and has not been independently verified unless it was seen at this
inspection.
Add quickly
Brand and model are remembered, so a run of
identical items needs only the serial each time.
Items
A tracked defect carries forward with its photographs, so the same wear can
be compared from one inspection to the next. The judgement on textiles is usually about the
rate of change rather than the condition on any one day.
Sign off
Six months is the common interval for equipment in frequent use. The
manufacturer’s instructions and the duty holder’s risk assessment govern.
One record per item. Where a batch shares a single marking, add a suffix so
each remains individually identifiable.
From the manufacturer’s instructions. Most textile equipment is limited to
10 years from manufacture; metal items commonly have no stated limit, in which case leave blank.
Photograph the marking or label to record the serial and date of manufacture,
and any defect. These stay with the item and appear in the report where relevant.
The intended use determines which regime applies to the device. Anchors for
restraint, arrest, positioning and rope access sit under the Work at Height Regulations and
BS 7883. Where a person is raised or lowered by mechanical means, further duties may arise.
Record what the device was specified for; use beyond that is a matter for the duty holder.
Where Bluco installed the device and also examines it, the report records
that fact. Installer-carried periodic inspection is accepted practice, but it is disclosed
rather than left unstated.
Examination of an anchor device is carried out against BS 7883 and the
manufacturer’s instructions, not against BS EN 12572. Include it only where you are
competent and engaged to examine it, and where doing so is within your insurance.
The annual service interval runs from 15 months after manufacture, and every
12 months thereafter.
The six-month inspection requires the unit to be dismounted.
Taken from the webbing tag inside the device near the shackle. The
manufacturer requires this date to be recorded in the inspection log, and recommends the
webbing be replaced after 1.5 years of use regardless of its condition.
—
—
Every check at this tier. Tap any line to go back to it.
Remedial action
Recording work as complete does not close the finding. It is closed when a
later inspection verifies it, which is what makes the record defensible.
Reissue
Reissuing produces the report again at a new revision. The record of what
was inspected is unchanged; only the revision and the reason for it are added.
Findings
Sign off
Where a report is reissued, increment the revision and state briefly what
changed. The amendment record appears in the report.
Selecting a statement fills the box below. Amend it if the circumstances of
this inspection differ; the wording used here is what appears in the report.
State the basis on which you are competent to assess this structure against the
standard. Rope access certification is an access qualification and is recorded separately below.
Declaration
Sign above